Prediction of Brobchodilator Response by Using FEF25~75% in Adult Patient with a Normal Spirometry Result.
Se Hwan Park, Seung Yup Lee, Seung Mo Kang, Choon Sik Seon, Hyun Kyung Kim, Byoung Hoon Lee, Jae Hyung Lee, Sang Hoon Kim
Division of Pulmology and Allergy, Department of Internal Medicine, Eulji Medical Center, Eulji University School of Medicine, Korea. hoonakr@eulji.ac.kr
Abstract
BACKGROUND
When patients with chronic respiratory symptoms have a normal spirometry result, it is not always easy to consider bronchial asthma as the preferential diagnosis. Forced expiratory flow between 25% and 75% of vital capacity (FEF(25~75%)) is known as a useful diagnostic value of small airway diseases. However, it is not commonly used, because of its high individual variability. We evaluated the pattern of bronchodilator responsiveness (BDR) and the correlation between FEF25~75% and BDR in patients with suspicious asthma and normal spirometry. METHODS: Among patients with suspicious bronchial asthma, 440 adult patients with a normal spirometry result (forced expiratory volume in one second [FEV1]/forced vital capacity [FVC] > or =70% & FEV1% predicted > or =80%) were enrolled. We divided this group into a positive BDR group (n=43) and negative BDR group (n=397), based on the result of BDR. A comparison was carried out of spirometric parameters with % change of FEV1 after bronchodilator (DeltaFEV1%). RESULTS: Among the 440 patients with normal spirometry, FEF(25~75%)% predicted were negatively correlated with DeltaFEV1% (r=-0.22, p<0.01), and BDR was positive in 43 patients (9.78%). The means of FEF(25~75%)% predicted were 64.0+/-14.5% in the BDR (+) group and 72.9+/-20.8% in the BDR (-) group (p<0.01). The negative correlation between FEF(25~75%)% predicted and DeltaFEV1% was stronger in the BDR (+) group (r=-0.38, p=0.01) than in the BDR (-) group (r=-0.17, p<0.01). In the ROC curve analysis, FEF(25~75%) at 75% of predicted value had 88.3% sensitivity and 40.3% specificity for detecting a positive BDR. CONCLUSION: BDR (+) was not rare in patients with suspicious asthma and normal spirometry. In these patients, FEF(25~75%)% predicted was well correlated with BDR.
Key Words: Bronchodilator Agents, Asthma


ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
FOR CONTRIBUTORS
Editorial Office
101-605, 58, Banpo-daero, Seocho-gu (Seocho-dong, Seocho Art-Xi), Seoul 06652, Korea
Tel: +82-2-575-3825, +82-2-576-5347    Fax: +82-2-572-6683    E-mail: katrdsubmit@lungkorea.org                

Copyright © 2024 by The Korean Academy of Tuberculosis and Respiratory Diseases. All rights reserved.

Developed in M2PI

Close layer
prev next