Comparison of blood gas analyser, pH meter and pH Strip methods in the measurement of pleural fluid pH.
Hyun Suk Jee, Yong Bum Park, Jae Chol Choi, Chang Hyuk Ahn, Ji Hoon Yoo, Jae Yeol Kim, In Won Park, Byoung Whui Choi
Abstract
BACKGROUND
pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the' gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. METHODS: From August 1999 to March 2000, were measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of plerual fluid was maintained around 0℃ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. RESULTS: The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean±SD) was 7.34±0.12 with blood gas analyser, 7.52±0.25 with pH meter, 7.37±0.16 with pH strip of immediate measurement and 6.93±0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods(p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). CONCLUSION: In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after fluid tapping.
Key Words: Pleural fluid pH, pH strip, pH meter, Blood gas analyser
TOOLS
METRICS Graph View
  • 0 Crossref
  •   Scopus
  • 1,173 View
  • 14 Download
Related articles


ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
FOR CONTRIBUTORS
Editorial Office
101-605, 58, Banpo-daero, Seocho-gu (Seocho-dong, Seocho Art-Xi), Seoul 06652, Korea
Tel: +82-2-575-3825, +82-2-576-5347    Fax: +82-2-572-6683    E-mail: katrdsubmit@lungkorea.org                

Copyright © 2024 by The Korean Academy of Tuberculosis and Respiratory Diseases. All rights reserved.

Developed in M2PI

Close layer
prev next