We report here on an uncommon case of mediastinitis that occurred after central venous catheterization. A patient with colon and jejunal cancer complained high fever, right shoulder pain, chest pain, and limited motion of the affected shoulder just 6 days after central venous catheterization. Bacterial culture of the blood, shoulder abscess, and catheter puncture site revealed methicillin-resistent staphylococcus aureus. Right upper mediastinal widening on chest film also suggested mediatinitis. Mediastiotomy and pus drainage was performed along with adequate antibiotics therapy. In this case, it seems that initially formed bacteria from the puncture site migrated to the mediastinum through the tissue plane to start the mediastinitis. Careful dressing of puncture site and correct handling of catheter is important to prevent this serious complication.
Key Words: Mediastinitis, Catheterization
TOOLS
METRICS Graph View
  • 0 Crossref
  •   Scopus
  • 1,613 View
  • 13 Download
Related articles

A Case of Pleural Effusion after Malposition of Central Venous Catheter.2006 June;60(6)



ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
FOR CONTRIBUTORS
Editorial Office
101-605, 58, Banpo-daero, Seocho-gu (Seocho-dong, Seocho Art-Xi), Seoul 06652, Korea
Tel: +82-2-575-3825, +82-2-576-5347    Fax: +82-2-572-6683    E-mail: katrdsubmit@lungkorea.org                

Copyright © 2024 by The Korean Academy of Tuberculosis and Respiratory Diseases. All rights reserved.

Developed in M2PI

Close layer
prev next